The brine filling of a eutectic plate absorbs heat as it melts, and the plate holds its melting point while it does. Two plates with the same total energy can therefore yield very different amounts in different bands: before counting kilojoules, look at where the melting point sits against the load's band.

For chilled goods a -3 °C plate works inside the band. A -21 °C plate puts the same load at risk of freezing, and most of its energy is spent outside the band the product needs. In a deep-frozen load it runs the other way: a -3 °C plate stays warmer than the product inside the box and warms the load instead of cooling it.

Three details are enough to choose a plate:

  1. The lowest and highest temperature the product accepts
  2. Transport time and outside temperature
  3. The container model

Send them to Aris Makina. We obtain GEBHARDT's free thermal analysis and pass it on; it calculates the longest time before the load reaches its limit temperature.