Aris Makina & Otomotiv
← Cold chain guide hub

What we have written on the cold chain41 / 154

More articles from the Isotec guide hub: choosing containers, eutectic plates, measurement, regulation and notes from the field.

Total time outside temperature limit
29 June 2026
Total time outside temperature limit

Two short events and one long event can produce the same total duration.

Read the article →
Test equipment in the real workflow at site acceptance
28 June 2026
Test equipment in the real workflow at site acceptance

Separate delivery inspection from performance acceptance. Define the load, route and measurement points first, then compare results with the agreed record.

Read the article →
Which cleaning form fields leave a useful trace?
28 June 2026
Which cleaning form fields leave a useful trace?

A useful form is defined by whether a record can be matched to a container and shift. Start with five fields and check completion.

Read the article →
Find unstarted recorders by matching run lists
28 June 2026
Find unstarted recorders by matching run lists

Match planned runs to downloaded files by ID; investigate unmatched runs without assuming the recorder was never started.

Read the article →
How to reconcile the thermal-container pool with physical stock
28 June 2026
How to reconcile the thermal-container pool with physical stock

At one cut-off time, match identity, status and location, then classify each difference by container.

Read the article →
What to record at thermal-container return intake
28 June 2026
What to record at thermal-container return intake

Before washing, record container ID, arrival time, previous load and initial condition observations.

Read the article →
Temperature rate-of-change alarm
28 June 2026
Temperature rate-of-change alarm

A fixed limit sounds only after it is crossed. The hard part of a rate alarm is telling a door opening from a real failure; here is how to set the hold time, the sensor position and the WHO requirements.

Read the article →
How are delivery decisions made without phone or internet?
28 June 2026
How are delivery decisions made without phone or internet?

Use pre-defined operating steps offline and keep product disposition separate.

Read the article →
Cold-chain KPI denominator definition
28 June 2026
Cold-chain KPI denominator definition

Explain the assessed total and missing records before interpreting a trip deviation rate.

Read the article →
How should a container be handed to maintenance?
28 June 2026
How should a container be handed to maintenance?

Record unit identity, cleaning state and requested work at maintenance handover; do not treat repair completion alone as release for reuse.

Read the article →
How can you measure cost sensitivity to energy prices?
27 June 2026
How can you measure cost sensitivity to energy prices?

Apply actual kWh, fuel, and invoice prices to scenarios; keep tariff and consumption assumptions separate.

Read the article →
Who records that a wash is finished?
27 June 2026
Who records that a wash is finished?

Tie the wash record to one clear check: the container, points inspected and the second checker should appear in the same record.

Read the article →