Compare TBX 600 and 725 dimensions accurately
8 January 2025
Compare TBX 600 and 725 dimensions accurately

Do not assume equal width or crate fit. Check external and internal dimensions for the exact model code, then trial with your packaging.

Read the article →
Will the TBX 410 fit? Dimensions and clearance
7 January 2025
Will the TBX 410 fit? Dimensions and clearance

Compare maker dimensions with door, vehicle and turning clearance; the TBX 410's 410 L volume alone does not show fit.

Read the article →
Verify conditions in a thermal report
6 January 2025
Verify conditions in a thermal report

Before interpreting a curve, verify the model, load, ambient conditions, sensor location and test method.

Read the article →
The difference between sublimation and phase change
5 January 2025
The difference between sublimation and phase change

Sublimation is the kind of phase change that goes straight from solid to gas, which is how dry ice is used up. A eutectic plate works between solid and liquid at a chosen melting point and is frozen again.

Read the article →
Assess ambient-temperature changes by measuring the real load
4 January 2025
Assess ambient-temperature changes by measuring the real load

The ambient-to-interior difference affects heat transfer; hold time may not change linearly. Record shade, wind and load.

Read the article →
How to ask for insulation performance in a quote
2 January 2025
How to ask for insulation performance in a quote

Compare quotes by lambda, panel U-value, complete-body performance and matched test conditions, then request the holding-hours protocol in writing.

Read the article →
Read a container warming curve from your route trial
1 January 2025
Read a container warming curve from your route trial

Simple curve models explain behaviour; they do not guarantee duration. Record sensor location and conditions with the actual load.

Read the article →
Align conditions when two devices disagree
31 December 2024
Align conditions when two devices disagree

Compare calibration status, sensor location and measurement time. Do not choose a reference until both devices measure the same item and point.

Read the article →
Check how a sensor cable affects the gasket line
30 December 2024
Check how a sensor cable affects the gasket line

If the cable affects lid closure, the measurement setup has changed. Verify a manufacturer-defined pass-through or route it outside the seal.

Read the article →
Monitor logger batteries in the cold using device data
29 December 2024
Monitor logger batteries in the cold using device data

Review battery performance by cell type, device and use conditions. If records have gaps, compare battery, temperature and communication logs.

Read the article →
Validate a glycol simulator against the product
28 December 2024
Validate a glycol simulator against the product

A glycol bottle imitates a defined thermal response; do not assume product equivalence. Trial its fill, volume and placement against the load.

Read the article →
Emissivity error in infrared thermometers
27 December 2024
Emissivity error in infrared thermometers

An infrared thermometer reads the radiation a surface emits. On a shiny surface it sees the reflection of its surroundings instead of the product's heat, so the acceptance decision rests on a probe placed between packs.

Read the article →